Cell Voltage Monitoring
CVM-32A

Essential performance for budget-sensitive applications.

A cell voltage monitoring (CVM) system tailored for research, testing and practical application of H2 fuel cells. The CVM system protects the integrity of individual cells and provides valuable data for predictive maintenance planning and performance optimization.

CVM-32A modules and sets are designed as a cost-effective solution mainly for hydrogen fuel cells applications with limited voltage range. These ready-to-use cell voltage monitor sets are easily integrated into specialized applications and allow direct connection to a PC via USBor to a PLC via RS-485 bus.

Explore our precision 2.5 V solutions with the CVM-64H module and sets, or 5 V solution with CVM-24P module and sets. For broader temperature and voltage monitoring requirements, consider our TEVOMET solutions.

Get My Offer Pricing & Orders All CVM Models

Product Introduction Video

See introduction to CVM features and practical live measurement demonstration of Kolibrik Cell Voltage Monitoring Sets.

Key Features

  • Modular and scalable design – 32 channels per module, up to 20 modules per system, supporting 640 channels
  • The best precision and resolution  – 12-bit resolution (1 mV), up to 100 sps @ ± 2.5 V
  • Galvanic isolation – safe operation and signal integrity (< 500 V, optionally additional up to 1 kV isolation)
  • 34-pin IDC connector (automotive-grade connectors on request)
  • Multiple communication options – USB, RS‑485
  • Standalone operation or software integration – with Kolibrik software or custom TCP/IP control

Sample Variant – Available on E-shop

CVM-S32A 1× CVM-32A: 24 channels total, RS-485/USB, 1× output, 1× input; Out of Box Solution
CVM-S64A 2× CVM-32A: 32 channels total, RS-485/USB, 2× output, 2× input; Out of Box Solution
CVM-S96A 3× CVM-32A: 64 channels total, RS-485/USB, 3× output, 3× input; Out of Box Solution
CVM-S128A 4× CVM-32A: 96 channels total, RS485/USB, 4× output, 4× input; Out of Box Solution
CVM-S160A 5× CVM-32A: 128 channels total, RS-485/USB, 5× output, 5× input; Out of Box Solution
CVM-E32A 1× CVM-32A: 32 additional channels, 1× output, 1× input; Extension for set

Technical Parameters

Channel count 32 channels per one CVM-24P module
Channel voltage range ± 1.5 V
Input impedance ≥ 100 MΩ
Isolation < 500 V between channels and XC2 bus
Additional up to 1 kV isolation can be provided by adding of controller modules
Sampling Channel multiplexing in selected range of used channels
12-bit ADC with up to 1 Msps internal sampling
All-channel sample rate up to 100 sps
Accuracy 0.1% of range + 0.1% of reading
Cell connection 34-pin IDC connector (automotive-grade connectors on request)
Communication bus RS-485: XC2 / Modbus RTU
Optional CAN bus and Modbus TCP communication with additional gateways
Compatible with other Kolibrik modules
Inputs / outputs Opto-isolated I/O with serial communication capability
Power supply 5 V DC / < 100 mA fom XC2 bus
8 … 30 V DC with Power supply module KMS-PWR
Application examples H2 fuel-cell tests stands
H2 fuel-cell application monitoring
Electrolyzers monitoring
Control systems
Dimensions CVM-32A module without enclosure
CVM-32A … CVM-S640A
CVM-E32A
 
85 × 58 × 13.5 mm
90 × 61 × (n*) × 16 + 24) mm
90 × 61 × 16 mm
*) n - number of 32-channel modules
Mounting DIN-rail and wall-mount holders for set enclosures
Single module without enclosure: 4× mounting hole 2.7 mm, hex spacers with M2.5 thread
Channel count examples Single CVM-32A module
CVM-S32A
CVM-S64A
CVM-S160A
CVM-E32A
32 channels
32channels
64channels
160 channels
additional 32 channels

Multiple modules can be daisy-chained to measure up to 640 channels, custom sets for more channels available.
Ambient operating temperature -40 °C to +85 °C
+85 °C to +125 °C module can be powered, measurement inactive

*) Channels are organized by groups of 4 channels. Channels in one group can measure up to ±20 V if the sum of group channels does not exceed 20 V. So, one channel can measure up to ±20 V, if other channels in group are short-circuited. Note that adjacent channels and groups are chained together and are not independent.

If these variants do not suit you, never mind! Tell us, what you exactly need – we offer customized solutions!


Documentation

Software

To run your experiments, you’ll use the application CVM Manager – our measurement and control app that manages everything from workstation setup to real-time data acquisition and visualization. Just connect the Cell Voltage Monitoring system, and let the science begin.

Gallery

Custom Design

We offer customization of model parameters, tailored mechanical and electrical setups, or as part of complete development services for custom projects and series production. Need something specific? Just tell us your key requirements — number of channels, interfaces or custom cables needs, custom enclosures, software functions, communication protocols, and any other application-specific constraints — we offer customized solutions!


Contact us

Ensure Longevity and Safety.
Talk to Our Experts About Your CVM Needs.

Help me choose Pricing & Orders All CVM Models

More About Fuel Cell & Electrolyzer Health & Safety Monitoring